Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 5.884
Filtrar
1.
ACS Appl Mater Interfaces ; 16(15): 19411-19420, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38588486

RESUMO

Zinc oxide (ZnO) is a widely employed material for enhancing the performance of cellulose-based triboelectric nanogenerators (C-TENGs). Our study provides a novel chemical interpretation for the improved output efficiency of ZnO in C-TENGs. C-TENGs exhibit excellent flexibility and integration, achieving a maximum open-circuit voltage (Voc) of 210 V. The peak power density is 54.4 µW/cm2 with a load resistance of 107 Ω, enabling the direct powering of 191 light-emitting diodes with the generated electrical output. Moreover, when deployed as self-powered sensors, C-TENGs exhibit prolonged operational viability and responsiveness, adeptly discerning bending and motion induced by human interaction. The device's sensitivity, flexibility, and stability position it as a promising candidate for a diverse array of energy-harvesting applications and advanced healthcare endeavors. Specifically, envisaging sensitized wearable sensors for human activities underscores the multifaceted potential of C-TENGs in enhancing both energy-harvesting technologies and healthcare practices.


Assuntos
Óxido de Zinco , Humanos , Fenômenos Físicos , Movimento (Física) , Celulose , Atividades Humanas
2.
PLoS One ; 19(4): e0301622, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38630695

RESUMO

This paper proposes a reinforced concrete (RC) boundary beam-wall system that requires less construction material and a smaller floor height compared to the conventional RC transfer girder system. The structural performance of this system subjected to axial compression was evaluated by performing a structural test on four specimens of 1/2 scale. In addition, three-dimensional nonlinear finite element analysis was also performed to verify the effectiveness of the boundary beam-wall system. Three test parameters such as the lower wall length-to-upper wall length ratio, lower wall thickness, and stirrup details of the lower wall were considered. The load-displacement curve was plotted for each specimen and its failure mode was identified. The test results showed that decrease in the lower wall length-to-upper wall length ratio significantly reduced the peak strength of the boundary beam-wall system and difference in upper and lower wall thicknesses resulted in lateral bending caused by eccentricity in the out-of-plane direction. Additionally, incorporating cross-ties and reducing stirrup spacing in the lower wall significantly improved initial stiffness and peak strength, effectively minimizing stress concentration.


Assuntos
Materiais de Construção , Compressão de Dados , Análise de Elementos Finitos , Fenômenos Físicos
3.
Sensors (Basel) ; 24(7)2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38610349

RESUMO

Seismocardiography (SCG), a method for measuring heart-induced chest vibrations, is gaining attention as a non-invasive, accessible, and cost-effective approach for cardiac pathologies, diagnosis, and monitoring. This study explores the integration of SCG acquired through smartphone technology by assessing the accuracy of metrics derived from smartphone recordings and their consistency when performed by patients. Therefore, we assessed smartphone-derived SCG's reliability in computing median kinetic energy parameters per record in 220 patients with various cardiovascular conditions. The study involved three key procedures: (1) simultaneous measurements of a validated hardware device and a commercial smartphone; (2) consecutive smartphone recordings performed by both clinicians and patients; (3) patients' self-conducted home recordings over three months. Our findings indicate a moderate-to-high reliability of smartphone-acquired SCG metrics compared to those obtained from a validated device, with intraclass correlation (ICC) > 0.77. The reliability of patient-acquired SCG metrics was high (ICC > 0.83). Within the cohort, 138 patients had smartphones that met the compatibility criteria for the study, with an observed at-home compliance rate of 41.4%. This research validates the potential of smartphone-derived SCG acquisition in providing repeatable SCG metrics in telemedicine, thus laying a foundation for future studies to enhance the precision of at-home cardiac data acquisition.


Assuntos
Doenças Cardiovasculares , Smartphone , Humanos , Reprodutibilidade dos Testes , Fenômenos Físicos , Benchmarking , Doenças Cardiovasculares/diagnóstico
4.
Elife ; 122024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38597934

RESUMO

Termites build complex nests which are an impressive example of self-organization. We know that the coordinated actions involved in the construction of these nests by multiple individuals are primarily mediated by signals and cues embedded in the structure of the nest itself. However, to date there is still no scientific consensus about the nature of the stimuli that guide termite construction, and how they are sensed by termites. In order to address these questions, we studied the early building behavior of Coptotermes gestroi termites in artificial arenas, decorated with topographic cues to stimulate construction. Pellet collections were evenly distributed across the experimental setup, compatible with a collection mechanism that is not affected by local topography, but only by the distribution of termite occupancy (termites pick pellets at the positions where they are). Conversely, pellet depositions were concentrated at locations of high surface curvature and at the boundaries between different types of substrate. The single feature shared by all pellet deposition regions was that they correspond to local maxima in the evaporation flux. We can show analytically and we confirm experimentally that evaporation flux is directly proportional to the local curvature of nest surfaces. Taken together, our results indicate that surface curvature is sufficient to organize termite building activity and that termites likely sense curvature indirectly through substrate evaporation. Our findings reconcile the apparently discordant results of previous studies.


Assuntos
Isópteros , Humanos , Animais , Consenso , Sinais (Psicologia) , Personalidade , Fenômenos Físicos
5.
PLoS One ; 19(4): e0301852, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38625980

RESUMO

In view of the growing role of magnetic particles under magnetic field influence in medical and other applications, and perforce the bead chaining, it is important to understand more generally the chain dynamics. As is well known, in the presence of a magnetic field, magnetic beads tend to form chains that are aligned with the magnetic field vector. In addition, if there is a magnetic field gradient, there will be a magnetic force acting on this chain. The main goal of the present research is to study the motion of a magnetic bead chain that makes an arbitrary angle with the magnetic force vector in the Stokes flow limit, that is, in the limit of zero Reynolds number. We used the public-domain computer program HYDRO++ to calculate the mobility matrix, which relates the magnetic force acting on the chain to the velocity of the chain, for a chain of N beads making an arbitrary angle with the magnetic force vector. Because of the presence of off-diagonal elements of the mobility matrix, as the chain is drawn in the direction of the magnetic force, it is also deflected to the side. We derived analytic solutions for this motion. Also, for bead chains moving in directions both parallel and perpendicular to their lengths, we fit three-parameter functions to solutions from HYDRO++. We found the fits to be excellent. Combining these results with the analytic solutions, we obtained expressions for the velocity components for the bead chains that provide excellent fits to HYDRO++ solutions for arbitrary angles. Finally, we apply the methodology used for the bead chain studies to the study of an obliquely falling rod in a viscous fluid and derive analytic solutions for the velocity components of the obliquely falling rod.


Assuntos
Magnetismo , Campos Magnéticos , Movimento (Física) , Fenômenos Físicos
6.
J Orthop Surg Res ; 19(1): 231, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38589910

RESUMO

BACKGROUND: Internal and external fixation are common surgical procedures for treating fractures. However, the impact of different surgical approaches (including internal and external fixations) on patients' psychological status and Quality of Life (QoL) is rarely examined. Herein, we aimed to investigate the effects of internal and external fixation on anxiety, depression, insomnia, and overall mental and physical health in Distal Radius Fractures (DRF) patients. METHODS: We performed a retrospective study on 96 fracture patients who underwent internal fixation (57 patients) or external fixation (39 patients). The Visual Analog Scale (VAS), the Hospital Anxiety and Depression Scale (HADS), the Athens Insomnia Scale (AIS), and the Medical Outcomes Study Short Form 36 (SF-36) questionnaire were used to assess the patients' pain, anxiety, depression, sleep, and QoL before surgery and at seven days, one month, and three months post-surgery. RESULTS: The VAS scores were significantly lower in the Internal Fixation Group (IFG) than in the External Fixation Group (EFG) on the seventh day and one month postoperatively (P < 0.05). Although both groups showed no significant anxiety, depression, or insomnia before surgery (P > 0.05), the EFG showed significantly higher HADS-A, HADS-D, and AIS scores than the IFG at seven days and one and three months postoperatively (P < 0.05). Additionally, changes in HADS-A, HADS-D, and AIS scores were most significant at day seven post-surgery in the EFG (P < 0.05). Furthermore, no significant difference was found between the two groups in the average Physical Component Summary (PCS) and Mental Component Summary (MCS) scores before surgery (P > 0.05). However, both groups showed positive changes in PCS and MCS scores at postoperative day seven and one and three months postoperatively, with the IFG having significantly higher average PCS and MCS scores compared to the EFG (P < 0.05). CONCLUSION: Compared to external fixation, internal fixation did not significantly impact patients' emotions regarding anxiety and depression in the early postoperative period, and physical and mental health recovery was better during the postoperative rehabilitation period. Furthermore, when there are no absolute indications, the impact on patients' psychological well-being should be considered as one of the key factors in the treatment plan during surgical approach selection.


Assuntos
Fraturas Ósseas , Distúrbios do Início e da Manutenção do Sono , Humanos , Qualidade de Vida , Distúrbios do Início e da Manutenção do Sono/etiologia , Fixadores Externos , Estudos Retrospectivos , Fixação de Fratura/efeitos adversos , Fixação Interna de Fraturas/efeitos adversos , Fenômenos Físicos
7.
J Texture Stud ; 55(2): e12832, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38613251

RESUMO

Puffed-grain food is a crispy snack whose consumer satisfaction depends on snack crispness and crunchiness, which can be characterized by the sound and the acoustic signals of food breaking. This study aimed to evaluate whether acoustic characteristics can be used to predict the crispness of various puffed-grain food. Sensory evaluation was performed on puffed-grain products with varying hygroscopic durations and different types. The relation between sensory evaluation and acoustic characteristics of nine different types of food was examined. The Hilbert-Huang transform was used to perform energy segmentation of the acoustic signal of puffed-grain food and observe its energy migration process. The results showed that energy release was more concentrated in the low-frequency range for grain-puffed foods with different hygroscopic durations. No notable correlation was observed between the low-frequency interval and sensory crispness for the different types of puffed-grain foods. However, the acoustic features extracted from their inherent low-frequency intervals showed a significantly improved correlation with sensory crispness. Therefore, it provides a theoretical reference for applying acoustic characteristics to describe food texture.


Assuntos
Acústica , Som , Grão Comestível , Fenômenos Físicos , Lanches
8.
J Texture Stud ; 55(2): e12823, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38613313

RESUMO

In 2017, the International Dysphagia Diet Standardisation Initiative (IDDSI) introduced the IDDSI flow test which enables patients, clinicians, caregivers, food service professionals and researchers to classify liquid thickness into five levels based on the volume of liquid remaining in a standard 10 mL slip tip syringe after 10 s of flow under gravity. Within a few months of publishing the IDDSI flow test instructions, several barriers emerged: (1) the preferred model of syringe (BD 303134) was not equally accessible around the world, causing some users to perform flow tests with alternate models of syringe; (2) differences in syringe geometry across models led to variations in IDDSI flow test results; and (3) the need to use a second syringe for sample loading added complexity and cost to end users. To address these barriers, IDDSI designed the IDDSI funnel, a novel device, which combines the geometry of the BD 303134 syringe with a kitchen funnel to facilitate easy loading of liquid samples without need for a second syringe. In this report, we compare the IDDSI flow test results across two devices: syringe BD 303134 and IDDSI funnel. IDDSI level classifications were in complete agreement with the syringe reference test results in 67/73 (92%) of the test fluids and temperature conditions with mean difference of residual liquid across devices of 0.2 (2% full scale). These results demonstrate excellent correspondence between the two devices.


Assuntos
Transtornos de Deglutição , Serviços de Alimentação , Humanos , Fenômenos Físicos , Temperatura
9.
PLoS One ; 19(3): e0299270, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38437196

RESUMO

The allocation of renewable energy plants, especially wind turbines, is stagnating in Germany. Although the citizens approve of the energy transition, they resist concrete local projects. In recent years, research has shown that interactive map applications support participatory planning through motivation, social interaction, and knowledge transfer. We aim to reduce biases against renewable energy (RE) and support informed decision making while accepting local responsibility. We hypothesized that finding a new gamified participation format, based on behavioral mechanisms, would strengthen the empowerment of people. To this end, we designed a dialogue tool and participation format, 'Vision:En 2040', which combines: (i) a precise target electricity yield, (ii) an interactive map showing results of people's actions, information about environmental impacts, and (iii) game rules which foster cooperation. In facilitated workshops, participants simulate the allocation of wind and photovoltaic power plants in their municipality to achieve a target electricity yield. The developed tool is based on methods of environmental planning and geoinformatics. 'Vision:En 2040' was systematically tested with a technical test and a pre-test. In addition, its impact on participants was assessed through surveys and qualitative content analysis. The evaluation results show that the tool can influence the acceptance of the energy transition in terms of attitude. Through 'Vision:En 2040', participants became aware of the community's responsibility in the energy transition and expanded their knowledge. In addition, decision makers used the workshop results to plan RE sites. Our results indicate that 'Vision:En 2040' is helpful for informal citizen participation in accelerating the energy transition.


Assuntos
Conscientização , Pesquisa Comportamental , Humanos , Fenômenos Físicos , Eletricidade , Alemanha
10.
PLoS One ; 19(3): e0299658, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38452038

RESUMO

To address the issues of tractors using too much fuel and not being energy efficient, a predictive control strategy based on Pontryagin's minimum principle integrating working condition prediction is proposed for agricultural hybrid tractors. The Dongfanghong 1804 tractor is being used for research. Firstly, the main parameters of the hybrid drive system are determined and modeled. Secondly, based on the adaptive cubic exponential forecasting method, the working condition information for a period of time in the future is predicted through historical working condition information. Furthermore, combining the predicted working conditions information, the goal is to minimize the total energy consumption cost of the entire machine. Motor power and diesel engine power are control variables. The battery state of charge is a state variable. Subsequently, a predictive control strategy based on Pontryagin's minimum principle integrating working condition prediction is proposed. Finally, the simulation test is carried out based on the MATLAB simulation platform. Research indicates: under plowing conditions, compared with the power following control strategy, the proposed predictive control strategy can effectively manage the performance of the diesel engine and motor, ensuring they operate at their most efficient level. The total energy consumption costs of the power following control and predictive control strategies are 37.17 China Yuan (CNY) and 33.67 CNY, respectively. The cost of energy used is decreased by 9. 42%, which helps make tractor field plowing more efficient and economical.


Assuntos
Agricultura , Motivação , Fenômenos Físicos , China , Simulação por Computador
11.
Nat Commun ; 15(1): 2160, 2024 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-38461256

RESUMO

Rotating magnetic fields enable biomedical microrobots to overcome physiological barriers and promote extravasation and accumulation in tumors. Nevertheless, targeting deeply situated tumors requires suppression of off-target actuation in healthy tissue. Here, we investigate a control strategy for applying spatially selective torque density to microrobots by combining rotating fields with magnetostatic selection fields. Taking magnetotactic bacteria as diffuse torque-based actuators, we numerically model off-target torque suppression, indicating the feasibility of centimeter to millimeter resolution for human applications. We study focal torque application in vitro, observing off-target suppression of actuation-dependent effects such as colonization of bacteria in tumor spheroids. We then design and construct a mouse-scale torque-focusing apparatus capable of maneuvering the focal point. Applying this system to a mouse tumor model increased accumulation of intravenously injected bacteria within tumors receiving focused actuation compared to non-actuated or globally actuated groups. This control scheme combines the advantages of torque-based actuation with spatial targeting.


Assuntos
Magnetismo , Neoplasias , Animais , Humanos , Camundongos , Torque , Fenômenos Físicos , Campos Magnéticos , Bactérias
12.
Radiol Cardiothorac Imaging ; 6(2): e230217, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38451189

RESUMO

Purpose To compare image quality, diagnostic performance, and conspicuity between single-energy and multi-energy images for endoleak detection at CT angiography (CTA) after endovascular aortic repair (EVAR). Materials and Methods In this single-center prospective randomized controlled trial, individuals undergoing CTA after EVAR between August 2020 and May 2022 were allocated to imaging using either low-kilovolt single-energy images (SEI; 80 kV, group A) or low-kiloelectron volt virtual monoenergetic images (VMI) at 40 and 50 keV from multi-energy CT (80/Sn150 kV, group B). Scan protocols were dose matched (volume CT dose index: mean, 4.5 mGy ± 1.8 [SD] vs 4.7 mGy ± 1.3, P = .41). Contrast-to-noise ratio (CNR) was measured. Two expert radiologists established the reference standard for the presence of endoleaks. Detection and conspicuity of endoleaks and subjective image quality were assessed by two different blinded radiologists. Interreader agreement was calculated. Nonparametric statistical tests were used. Results A total of 125 participants (mean age, 76 years ± 8; 103 men) were allocated to groups A (n = 64) and B (n = 61). CNR was significantly lower for 40-keV VMI (mean, 19.1; P = .048) and 50-keV VMI (mean, 16.8; P < .001) as compared with SEI (mean, 22.2). In total, 45 endoleaks were present (A: 23 vs B: 22). Sensitivity for endoleak detection was higher for SEI (82.6%, 19 of 23; P = .88) and 50-keV VMI (81.8%, 18 of 22; P = .90) as compared with 40-keV VMI (77.3%, 17 of 22). Specificity was comparable among groups (SEI: 92.7%, 38 of 41; both VMI energies: 92.3%, 35 of 38; P = .99), with an interreader agreement of 1. Conspicuity of endoleaks was comparable between SEI (median, 2.99) and VMI (both energies: median, 2.87; P = .04). Overall subjective image quality was rated significantly higher for SEI (median, 4 [IQR, 4-4) as compared with 40 and 50 keV (both energies: median, 4 [IQR, 3-4]; P < .001). Conclusion SEI demonstrated higher image quality and comparable diagnostic accuracy as compared with 50-keV VMI for endoleak detection at CTA after EVAR. Keywords: Aneurysms, CT, CT Angiography, Vascular, Aorta, Technology Assessment, Multidetector CT, Abdominal Aortic Aneurysms, Endoleaks, Perigraft Leak Supplemental material is available for this article. © RSNA, 2024.


Assuntos
Angiografia por Tomografia Computadorizada , Endoleak , Idoso , Humanos , Masculino , Aorta , Endoleak/diagnóstico por imagem , Fenômenos Físicos , Estudos Prospectivos , Feminino
13.
Bioinspir Biomim ; 19(3)2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-38430560

RESUMO

In animal and robot swimmers of body and caudal fin (BCF) form, hydrodynamic thrust is mainly produced by their caudal fins, the stiffness of which has profound effects on both thrust and efficiency of swimming. Caudal fin stiffness also affects the motor control and resulting swimming gaits that correspond to optimal swimming performance; however, their relationship remains scarcely explored. Here using magnetic, modular, undulatory robots (µBots), we tested the effects of caudal fin stiffness on both forward swimming and turning maneuver. We developed six caudal fins with stiffness of more than three orders of difference. For aµBot equipped with each caudal fin (andµBot absent of caudal fin), we applied reinforcement learning in experiments to optimize the motor control for maximizing forward swimming speed or final heading change. The motor control ofµBot was generated by a central pattern generator for forward swimming or by a series of parameterized square waves for turning maneuver. In forward swimming, the variations in caudal fin stiffness gave rise to three modes of optimized motor frequencies and swimming gaits including no caudal fin (4.6 Hz), stiffness <10-4Pa m4(∼10.6 Hz) and stiffness >10-4Pa m4(∼8.4 Hz). Swimming speed, however, varied independently with the modes of swimming gaits, and reached maximal at stiffness of 0.23 × 10-4Pa m4, with theµBot without caudal fin achieving the lowest speed. In turning maneuver, caudal fin stiffness had considerable effects on the amplitudes of both initial head steering and subsequent recoil, as well as the final heading change. It had relatively minor effect on the turning motor program except for theµBots without caudal fin. Optimized forward swimming and turning maneuver shared an identical caudal fin stiffness and similar patterns of peduncle and caudal fin motion, suggesting simplicity in the form and function relationship inµBot swimming.


Assuntos
Procedimentos Cirúrgicos Robóticos , Robótica , Animais , Natação , Fenômenos Biomecânicos , Fenômenos Físicos , Nadadeiras de Animais
14.
Sci Rep ; 14(1): 5457, 2024 03 05.
Artigo em Inglês | MEDLINE | ID: mdl-38443433

RESUMO

The effects of boiling water treatment on the physical properties of Quercus variabilis virgin cork (Qv VC) were examined and compared with those of Quercus suber reproduction cork (Qs RC). The water treatment was conducted at 100 °C for 1 h. Qv VC showed a significantly higher dimensional change in the three directions and lower weight loss than Qs RC by boiling water treatment. Untreated and boiled Qv VC showed higher density, air-dried moisture content, red/green (a*) and yellow/blue (b*) chromaticity, overall color change, shrinkage in all three directions, moisture adsorption on the entire surface, and swelling per 1% moisture content than untreated and boiled Qs RC. However, the lightness (L*) and water absorption on each surface were higher for Qs RC than for Qv VC. Moisture adsorption on each surface was comparable before and after heat treatment for both species. After boiling water treatment, the air-dried moisture content, dimensions, volume shrinkage, water absorption, and moisture adsorption on each surface and the entire surface increased, whereas L*, a*, b*, and swelling per 1% moisture content decreased. The results of the present study could be useful for further utilization of Qv cork growing in Korea.


Assuntos
Hipertermia Induzida , Quercus , Fenômenos Físicos , Adsorção , Fatores de Transcrição , Água , República da Coreia
15.
Chemosphere ; 355: 141686, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38513952

RESUMO

The oxygenation process of the catalyst surface, the incident-light harvesting capability, and facile recycling of utilized photocatalysts play key role in the outstanding photocatalytic performances. The typical existing photocatalysts in powder form have many drawbacks, such as difficult separation from the treated water, insufficient surface oxygenation, poor active surface area, low incident-light harvesting ability, and secondary pollution of the environment. A great number of scientific works introduced novel and fresh ideas related to designing floating photocatalytic systems by immobilizing highly active photocatalysts onto a floatable substrate. Thanks to direct contact with the illuminated light and oxygen molecules in the interface of water/air, the photocatalytic performance is maximized through production of more reactive species, employed in the photocatalytic reactions. Furthermore, facile recovering of the utilized photocatalysts for next processes avoids secondary pollution as well as diminishes the process's price. This review highlights the performance of developed floating photocatalysts for diverse applications. Furthermore, different floating substrates and possible mechanisms in floating photocatalysts are briefly mentioned. In addition, several emerging self-floating photocatalytic systems are taken attention and discussed. Specially, coupling photo-thermal and photocatalytic effects seems to be a good strategy for introducing a new class of floating photocatalyst to utilize the free, abundant, and green sunlight energy for the aims of water desalination and purification. Despite of a large number of attempts about the floating photocatalysts, there are still plenty of rooms for more in-depth research to be carried out for attaining the required characteristics of the large scale utilizations of these materials.


Assuntos
Poluição Ambiental , Oxigênio , Fenômenos Físicos , Reciclagem , Água
16.
Int J Biol Macromol ; 264(Pt 2): 130800, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38548501

RESUMO

The surface morphologies of polymer films have been used to improve the performance or enable new applications of films, such as controllable adhesion, shape morphing and light management. However, complicated and destructive methods were applied to produce surface morphologies on chitosan (CS) film. To overcome this challenge, we report an evaporation-induced self-assembly to form the tunable morphologies on the surface of short-chain chitosan film by varying the evaporation rates that influence the aggregation behavior of polymer chains between order and disorder. It enables the simple, tunable and scalable fabrication of surface morphologies on CS film (CS solution concentration: 2 wt%, drying from room temperature (RT) to 80 °C) that provides controllable haze (3-74 %) and high transmittance (>85 %) for the production of hazy and transparent window coatings. This simple approach to producing tunable surface morphologies could inspire the synthesis of multifunctional polymer films with different surface structures, whose applications can be extended to cell culture interfaces, flexible bioelectronic and optoelectronic devices.


Assuntos
Quitosana , Quitosana/química , Polímeros , Fenômenos Físicos
17.
Proc Natl Acad Sci U S A ; 121(14): e2317492121, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38547056

RESUMO

Energy metabolism is highly interdependent with adaptive cell migration in vivo. Mechanical confinement is a critical physical cue that induces switchable migration modes of the mesenchymal-to-amoeboid transition (MAT). However, the energy states in distinct migration modes, especially amoeboid-like stable bleb (A2) movement, remain unclear. In this report, we developed multivalent DNA framework-based nanomachines to explore strategical mitochondrial trafficking and differential ATP levels during cell migration in mechanically heterogeneous microenvironments. Through single-particle tracking and metabolomic analysis, we revealed that fast A2-moving cells driven by biomimetic confinement recruited back-end positioning of mitochondria for powering highly polarized cytoskeletal networks, preferentially adopting an energy-saving mode compared with a mesenchymal mode of cell migration. We present a versatile DNA nanotool for cellular energy exploration and highlight that adaptive energy strategies coordinately support switchable migration modes for facilitating efficient metastatic escape, offering a unique perspective for therapeutic interventions in cancer metastasis.


Assuntos
Amoeba , Linhagem Celular Tumoral , Movimento Celular , Fenômenos Físicos
18.
Med Phys ; 51(4): 2398-2412, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38477717

RESUMO

BACKGROUND: Cone-beam CT (CBCT) has been extensively employed in industrial and medical applications, such as image-guided radiotherapy and diagnostic imaging, with a growing demand for quantitative imaging using CBCT. However, conventional CBCT can be easily compromised by scatter and beam hardening artifacts, and the entanglement of scatter and spectral effects introduces additional complexity. PURPOSE: The intertwined scatter and spectral effects within CBCT pose significant challenges to the quantitative performance of spectral imaging. In this work, we present the first attempt to develop a stationary spectral modulator with flying focal spot (SMFFS) technology as a promising, low-cost approach to accurately solving the x-ray scattering problem and physically enabling spectral imaging in a unified framework, and with no significant misalignment in data sampling of spectral projections. METHODS: To deal with the intertwined scatter-spectral challenge, we propose a novel scatter-decoupled material decomposition (SDMD) method for SMFFS, which consists of four steps in total, including (1) spatial resolution-preserved and noise-suppressed multi-energy "residual" projection generation free from scatter, based on a hypothesis of scatter similarity; (2) first-pass material decomposition from the generated multi-energy residual projections in non-penumbra regions, with a structure similarity constraint to overcome the increased noise and penumbra effect; (3) scatter estimation for complete data; and (4) second-pass material decomposition for complete data by using a multi-material spectral correction method. Monte Carlo simulations of a pure-water cylinder phantom with different focal spot deflections are conducted to validate the scatter similarity hypothesis. Both numerical simulations using a clinical abdominal CT dataset, and physics experiments on a tabletop CBCT system using a Gammex multi-energy CT phantom and an anthropomorphic chest phantom, are carried out to demonstrate the feasibility of CBCT spectral imaging with SMFFS and our proposed SDMD method. RESULTS: Monte Carlo simulations show that focal spot deflections within a range of 2 mm share quite similar scatter distributions overall. Numerical simulations demonstrate that SMFFS with SDMD method can achieve better material decomposition and CT number accuracy with fewer artifacts. In physics experiments, for the Gammex phantom, the average error of the mean values ( E RMSE ROI $E^{\text{ROI}}_{\text{RMSE}}$ ) in selected regions of interest (ROIs) of virtual monochromatic image (VMI) at 70 keV is 8 HU in SMFFS cone-beam (CB) scan, and 19 and 210 HU in sequential 80/120 kVp (dual kVp, DKV) CB scan with and without scatter correction, respectively. For the chest phantom, the E RMSE ROI $E^{\text{ROI}}_{\text{RMSE}}$ in selected ROIs of VMIs is 12 HU for SMFFS CB scan, and 15 and 438 HU for sequential 80/140 kVp CB scan with and without scatter correction, respectively. Also, the non-uniformity among selected regions of the chest phantom is 14 HU for SMFFS CB scan, and 59 and 184 HU for the DKV CB scan with and without a traditional scatter correction method, respectively. CONCLUSIONS: We propose a SDMD method for CBCT with SMFFS. Our preliminary results show that SMFFS can enable spectral imaging with simultaneous scatter correction for CBCT and effectively improve its quantitative imaging performance.


Assuntos
Tomografia Computadorizada de Feixe Cônico Espiral , Processamento de Imagem Assistida por Computador/métodos , Espalhamento de Radiação , Fenômenos Físicos , Imagens de Fantasmas , Tomografia Computadorizada de Feixe Cônico/métodos , Artefatos , Algoritmos
19.
Int J Mol Sci ; 25(6)2024 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-38542384

RESUMO

We present ionization cross sections of hydrogen molecules by electron and positron impact for impact energies between 20 and 1000 eV. A three-body Classical Trajectory Monte Carlo approximation is applied to mimic the collision system. In this approach, the H2 molecule is modeled by a hydrogen-type atom with one active electron bound to a central core of effective charge with an effective binding energy. Although this model is crude for describing a hydrogen molecule, we found that the total cross sections for positron impact agree reasonably well with the experimental data. For the electron impact, our calculated cross sections are in good agreement with the experimental data in impact energies between 80 eV and 400 eV but are smaller at higher impact energies and larger at lower impact energies. Our calculated cross sections are compared with the scaled cross sections obtained experimentally for an atomic hydrogen target. We also present single differential cross sections as a function of the energy and angle of the ejected electron and scattered projectiles for a 250 eV impact. These are shown to agree well with available data. Impact parameter distributions are also compared for several impact energies.


Assuntos
Elétrons , Hidrogênio , Água/química , Fenômenos Físicos , Método de Monte Carlo
20.
ACS Appl Mater Interfaces ; 16(14): 17145-17162, 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38534071

RESUMO

The fabrication of antifouling zwitterionic polymer brushes represents a leading approach to mitigate nonspecific adhesion on the surfaces of medical devices. This investigation seeks to elucidate the correlation between the material composition and structural attributes of these polymer brushes in preventing protein adhesion. To achieve this goal, we modeled three different zwitterionic brushes, namely, carboxybetaine methacrylate (CBMA), sulfobetaine methacrylate (SBMA), and (2-(methacryloyloxy)ethyl)-phosphorylcholine (MPC). The simulations revealed that elevating the grafting density enhances the structural stability, hydration strength, and resistance to protein adhesion exhibited by the polymer brushes. PCBMA manifests a more robust hydration layer, while PMPC demonstrates the slightest interaction with proteins. In a comprehensive evaluation, PSBMA polymer brushes emerged as the best choice with superior stability, enhanced protein repulsion, and minimally induced protein deformation, resulting in effective resistance to nonspecific adhesion. The high-density SBMA polymer brushes significantly reduce the level of protein adhesion in AFM testing. In addition, we have pioneered the quantitative characterization of hydration repulsion in polymer brushes by analyzing the hydration repulsion characteristics at different materials and graft densities. In summary, our study provides a nuanced understanding of the material and structural determinants influencing the capacity of zwitterionic polymer brushes to thwart protein adhesion. Additionally, it presents a quantitative elucidation of hydration repulsion, contributing to the advancement and application of antifouling polymer brushes.


Assuntos
Polímeros , Proteínas , Polímeros/química , Fenômenos Físicos , Adsorção , Metacrilatos/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA